{"id":2607,"date":"2023-03-21T06:53:14","date_gmt":"2023-03-21T06:53:14","guid":{"rendered":"https:\/\/flow-force.com\/?post_type=product&p=2607"},"modified":"2023-03-21T12:50:10","modified_gmt":"2023-03-21T12:50:10","slug":"explosion-isolation-chemical","status":"publish","type":"product","link":"https:\/\/flow-force.com\/product\/explosion-isolation-chemical\/","title":{"rendered":"Explosion Isolation Chemical"},"content":{"rendered":"

IPD Isolation System – Activation<\/strong><\/h4>\n

The standard IPD Isolation System Detector is pressure driven. Mounted to the equipment in which the explosive event may occur, three pressure sensors respond to the early stages of the pressure wave that precedes the fireball in a deflagration. One of these pressure sensors is set low and provides early warning through the System Monitor of a process condition upset that may cause an unusually high system operating pressure; this is used to prevent system discharge due to non explosive process pressure excursions. When two of the three pressure sensors respond, the Isolation System is activated.<\/p>\n

Alternative IPD Isolation System activation can be accommodated. Examples include:<\/p>\n